MAX Implants

4 Connections, Wide Diameter Implants for Molar Replacements

The award-winning MAX dental implant systems feature a body with a larger-than-conventional diameter to fill the molar site, ultimately achieving remarkable primary stability from engagement with the perimeter bony wall.

Innovative ProductsContact Us

MAX Implants

4 Connections, Wide Diameter Implants for Molar Replacements

The award-winning MAX dental implant systems feature a body with a larger-than-conventional diameter to fill the molar site, ultimately achieving remarkable primary stability from engagement with the perimeter bony wall.

Innovative ProductsContact Us

MAX Dental Implants

The MAX tapered dental implant system is the first to allow for immediate placement into a multi-rooted molar extraction site.

Challenge

A conventional implant is not suited for immediate placement in the molar extraction socket. As a result, waiting periods of three to four months are necessary to allow for healing of the socket prior to implant placement. Often, the healed extraction site presents reduced bone height, inadequate for implant placement without a bone augmentation procedure.

Innovation

The award-winning MAX dental implant systems feature a body with a larger-than-conventional diameter to fill the molar site, ultimately achieving primary stability from engagement with the inter-radicular bone.. With tapered dental implant bodies and an enhanced surface, the MAX tapered dental implant is designed to fit the natural shape of the molar socket. The end result is an optimal implant fit in the multi-rooted immediate extraction site that minimizes bone loss and reduces treatment time.

Awards

  • American Academy of Osseointegration (AO) – Best Innovation Award, 2008
  • The SABS – Design Excellence Award – Medical Devices, 2010

Technical Facts

  • 7mm, 8mm and 9mm diameter, (6mm diameter External Hex MSc only)
  • Greater degree of taper
  • 7mm, 9mm, and 11mm lengths
  • Enhanced surface
  • Available in External Hex, Internal Hex Tri-Nex and Internal Octagon connections

Surgical and Prosthetic Benefits

  • Fits multi-rooted molar socket and allows for immediate placement following extraction
  • Maximizes bone preservation
  • Minimizes need for bone grafting
  • Avoids adjacent tooth roots
  • Increases patient acceptance
  • Reduces treatment time
  • Ability to use standard surgical protocol and instrumentation with minimal additions
  • Ability to use compatible prosthetic components by “platform switching”

Atieh MA, Alsabeeha NHM, Duncan WJ, de Silva RK, Cullinan MP Schwass D, Payne AGT. Immediate single implant restorations in mandibular molar extraction sockets: a controlled clinical trial. Clin. Oral Impl. Res. 24, 2013, 484-496 doi: 10.1111/j.1600-0501.2011.02415.x.

Atieh MA, Payne AGT, Duncan WJ, de Silva RK, Cullinan, MP. Immediate Placement or Immediate Restoration/Loading of Single Implants for Molar Tootth Replacement: A Systematic Review and Meta-analysis. The International Journal of Oral & Maxillofacial Implants. 2010, Volume 25, Number 1, 401-415.

Atieh MA, Alsabeeha NHM, Payne AGT, Schwass DR, Duncan WJ. Insertion torque of immediate wide-diameter implants: A finite analysis. Quintessence Int. 2012;43:e115-e126.

Hattingh AC, De Bruyn H, Ackermann A, Vandeweghw S. Immediate Placement of Ultrawide-Diameter Implants in Molar Sockets: Description of a Recommended Technique. Int J Periodontics Restorative Dent 2018;38:17-23. doi: 10.11607/prd.3433.

Egbert N, Ahuja S, Selecman A, Wicks R. Single tooth restoration in the maxilla with an ultra-wide diameter implant: A clinical report. J Adv Oral Res 2016;7(3):41-45.

Smith RB, Tarnow DP. Classification of Molar Extraction Sites for Immediate Dental Implant Placement: Technical Note. The International Journal of Oral & Maxillofacial Implants. 2013;28:911-916: doi 10.11607/jomi.2627.

Vandeweghe S, Ackermann A, Bronner J, Hattingh A, Tschakaloff A, De Bruyn H. A Retrospective, Multicenter Study on a Novo Wide-Body Implant for Posterior Regions. Clinical Implant Dentistry and Related Research. 2009, 1-12. Doi 10.1111/j.1708-8208.2009.00253.x.

Vandeweghe S, De Bruyn H. A within-implant comparison to evaluate the concept of platform switching. A randomized controlled trial. Eur J Oral Implantol 2012;5(3):253-262.

Vandeweghe S, Hattingh A, Wennerberg A, De Bruyn H. Surgical Protocol and Short-Term Clinical Outcome of Immediate Placement in Molar Extraction Sockets Using a Wide Body Implant.
J Oral Maxillofac Res 2011 (Jul-Sep);2(3):e1.

Vandeweghe S, De Ferrerre R, Tschakaloff A. De Bruyn H. A Wide-Body Implant as an Alternative for Sinus Lift or Bone Grafting. J Oral Maxillofac Surg 2011;69:e67-e74

Downloadable Documents

For further detailed information about the MAX Implant, please see the documents made available for your reference.

MAX Information Leaflet
Download PDFThe immediate placement of a conventional dental implant into a molar extraction socket poses a number of dlfflcultles.
Most significantly…
Southern Implants Product Brochure
Download PDFDental implants are an indispensable part of dental treatment options. With the globalization of medical infrastructures and higher standards of living , implant applications continue to increase…
MAX Implant Protocol
Download PDFA revolutionary innovation for the immediate placement into a molar extraction socket
The immediate placement of a conventional dental implant into a molar extraction socket poses a number of difficulties. Most significantly, the size and shape…

Innovative Treatment Solutions

Drop us a line anytime, and one of our customer service reps will respond to you as soon as possible.
South Africa - Head Office: 1 Albert Road, Irene, Centurion, RSA

Pin It on Pinterest

Share This